Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 247

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

(b) Memory flap
While the flap is operating if the AIRFLOW button is pushed once,
it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically
set to the angle when next operation is started.
(c) Swing flap
Flap moves in upward and downward directions continuously.
(2) Back-up Switch
When the remote controller batteries become weak, or if the remote controller is lost or malfunctioning, this switch may be used to
turn the unit on and off.
(a) Operation
Push the switch once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by
sensor), whether to go into the cooling, thermal dry or heating modes.
Function
Room temperature
setting
Operation mode
Cooling
About 26˚C
Thermal dry
About 25˚C
Heating
About 25˚C
On operating in automatic operation mode by back-up switch, functions shown in the above table are not altered, white, the other micro-
computer control functions remain effective.
(3) AUTOMATIC operation
(a) When starting operation after more than 1 hour since operation stops
(Operation stop button ON or ON-Timer), this system operates indoor fan with Lo for 20 seconds checks room temperature
and allowing decision of operating mode automatically.
Operation Mode
Note (1)
Operating Mode is not altered due to change of room temperature.
When intended to change operating mode, switch operation change over dial to the intended mode.
(b) Established temperature (operate by the established temperature button on remote controller).
-6
Cooling
20
Thermal dry
19
Fan speed
Flap
Auto
Natural flow
ON/OFF
Back-up switch
21˚C≤Room temperature<26˚C
=
Dry
Wireless remote control signal (Indication)
-5
-4
-3
-2
21
22
23
24
20
21
22
23
• Recommendable stopping angle of the flap
COOL DRY
Timer switch
Continuous
26˚C≤Room temperature
=
Cooling
±0
-1
+1
+2
25
26
27
28
24
25
26
27
SCM-C
Horizontal
blowing
+3
+4
+5
+6
29
30
31
32
28
29
30
31
245