2.1
GENERAL INFORMATION
2.1.1 Specific features
The "Mitsubishi Daiya" room air conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and
outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment with opera-
tion control switch and the outdoor unit is composed of condensing unit with compressor.
(1) Remote control flap
The flap can be automatically controlled by operating wireless remote control.
¡ AUTO (Natural flow) : Flap operation is automatically control.
¡ Swing
¡ Memory flap
(2) Automatic Operation
When the remote control switch is set on "auto", it will either automatically decide operation mode such as cooling, heating and
thermal dry, or operate in the operation mode before it has been turned to automatic control.
(3) Self diagnosis Function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as
follows.
TIMER lamp is
light up.
RUN lamp is light
up.
2.1.2 How to read the model name
Example :
SR K
: This will swing the flap up and down.
: Once the flap position is set, the unit memorizes the position and continues to operate at the same
position from the next time.
RUN lamp is flashing.
(1 Time flash.)
RUN lamp is flashing.
(2 Time flash.)
RUN lamp is flashing.
(6 Time flash.)
TIMER lamp is flashing.
(5 Time flash.)
50
1
H
EN
F - L
}
Abnormality of heat
exchanger thermistor.
No lamps will flashing
when the unit is operating.
Abnormality of room
temperature thermistor.
Abnormality of indoor
fan motor.
Abnormality of outdoor
unit.
CE marking model
Flare connecting
Applicable power source ...... See the specifications
Heat pump type
Series No.
Product capacity
Wall mounted type room air-conditioner
Split type room air-conditioner
SRK-H
53