Installation Of Indoor Unit - Mitsubishi Heavy Industries SRK25GZ-L1 Handbook

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

FDKN-H

12.5.1 Installation of indoor unit

All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions
do not cover all variations for every kind of installation circumstance. Should further information be desired or should
particular problems occur, the matter should be referred to Mitsubishi Heavy Industries, Ltd. through your local distributor.
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION
AND/OR PROPERTY DAMAGE.
(1) Selection of installation location
120 or more
FDKN208 type
Dimension
A
65
(2) Cautions for use of wireless remote controller
(a)
Opareting distance of wireless remote controller
Floor
Relation between illumination at receiver
unit and operating distance
(b)
Cautlons for operation
1)
Orient the remote control switch properly toward the receiver of the unit.
2)
Operating distance is as shown above but it may vary largely depending on the conditions.
3)
Effective distance may be shortened and the receiving may be disturbed when the receiver is under the condition of
direct exposure to sunlight or other strong light like electric bulb, dust is accumulated on it and it is shielded with a
curtain, etc.
498
NOTICE
WARNING
(a)
Select the installation location that meets the following conditions and obtain
the customer's consent.
1)
Location where cold and warm air spread all over the room
Unit: mm
2)
Location where piping and wiring to the outdoors can easily be laid down.
3)
Location where the drain can be discharged completely.
4)
Location where the wall to mount the unit is rigid.
5)
Location where there is no wind obstruction to the return air and supply
120 or more
air grills.
6)
Location not exposed to direct sunshine.
7)
Avoid the location exposed to oil splash or vapor.
8)
Avoid the location near to the machine emitting high-frequency radio wave.
FDKN258 · 308 type
9)
Avoid the location where the receiver of remote control is subject to
90
strong illumination.
10) Select the location where the unit can securely be operated by the wire-
less remote controller referring to the Article "Effective distance of wire-
less remote controller" indicated at the backside.
11) Secure the space for inspection and maintenance work.
Wireless remote con-
troller
Within 5 m
Illumination over suction grill-800 lus.
(Plan view)
60°
Within 60°
Caution item for close installation of
multiple units
(Plan view)
Effective scope
Effective scope
60°
60°
[Condition] Illumination at suction grill face 800 lux

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk35gz-l1Srk502z-l1Srk502z-lSrk328henf-l2Srk408henf-l2Srk501henf-l ... Show all

Table of Contents