2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

(3) Operation chart
The Multi series is a system that allows for different models and capacities of indoor units to be combined so the individual
operating characteristics of the indoor and outdoor are provided. Use the procedure shown in Item (c) to calculate the combined
operating characteristics.
(a) Operating characteristic of outdoor unit
Item
Cooling input
Heating input
Cooling running current
Heating running current
Inrush current (L.R.A)
Cooling power factor
Heating power factor
Note (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 "UNITARY AIR-CONDITIONERS"
(b) Operating characteristic of indoor unit
FDT Series
Model
Item
Power input (kW)
Running current (A)
FDR Series
Model
Item
Power input (kW)
Running current (A)
Notes (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 "UNITARY AIR-CONDITIONERS"
(2) The values shown in the above table are common to both cooling and heating operations.
(c) Calculation of total operation characteristics
Since the operation characteristics of series Multi depend on combination of indoor unit, calculate the total operation charac-
teristics of the system by using the formulas below according to specifications of each indoor unit or outdoor unit.
1)Total power input
Total power input (kW) = Power input of outdoor unit + ∑ (Power input of indoor unit)
2)Total running current
Total running current (A) = Running current of outdoor unit + [∑ (Running current of indoor unit) × 2/3]
3)Total power factor
Total power factor (%) = [Total power input (W) / √
Total operation characteristics = Operation characteristic value of outdoor unit + Operation characteristic value of indoor unit
[Example]
(Conditions)
Model
FDC508HES3
5.03/5.28
kW
4.58/4.71
A
A
%
FDT Series
208-A
258-A
308-A
0.10/0.11
0.11/0.12
0.5/0.5
0.6/0.6
FDR Series
208-A
258-A
308-A
0.10/0.11
0.11/0.12
0.15/0.16
0.5/0.5
0.7/0.7
Operation Voltage ········Indoor unit: 220 V, 50 Hz
Operation mode ··········· Cooling and Heating
Unit·······························Outdoor unit: FDC808HES3 × 1 unit
FDC808HES3
8.44/8.54
6.44/6.64
8.6/9.4
14.2/13.5
8.1/9.0
11.6/11.2
74
99
89/78
90/88
86/73
84/82
(220 V/240 V)
408-A
508-A
0.21/0.21
0.27/0.27
1.2/1.2
1.4/1.4
(220 V/240 V)
408-A
508-A
0.19/0.19
0.24/0.24
0.9/0.9
1.2/1.2
3 × Total running current (A) × Power source] × 100
Outdoor unit: 380 V, 50 Hz
Indoor unit: FDT308-A × 1 units, FDT508-A × 1 units
V MULTI
(380 V/415 V)
FDC1008HES3
11.92/12.02
9.72/9.92
20.0/19.0
16.5/16.0
154
91/88
90/86
687