Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 72

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

SRK-H
(a) Comfort timer settings
Temperature is checked beginning 1 hour before the set time, and the power is turned on before the timer setting as necessary to
bring the temperature to the proper level by the set time.
Operation mode
Room temperature sensor (Th
Heating
Cooling
(b) Timer time setting
The turn-off timer and turn-on timer can be set for up to 24 (32, 40: 12) hours in units of 1 hour.
(c) Night time turn off
Placing the timer to this setting changes the temperature setting of the indoor set button as follows:
Cooling, thermaldry
Temperature
setting (˚C)
Timer operation
(time)
Start
Note (1) The unit performs heating to the set time after 2.0 hours in the night time as shown right.
(d) Temperature adjustment
1)
Temperature adjustment setting may be set between 18 and 30˚C.
2)
The compressor and outdoor fan and turned on and off as shown below according to the temperature setting.
Cooling
Compressor
outdoor fan
3)
During the continuous mode, the compressor runs continuously in both cooling and heating. For thermal dry, please refer to
page 73.
70
Operating start time (amount of time
)
1
previous to set time that operation begins)
Under 5˚C
Under 10˚C
Under 15˚C
Over 15˚C
Over 40˚C
Over 35˚C
Over 30˚C
Under 30˚C
Heating
Temperature
setting (˚C)
Timer operation
(time)
Set temp.
Room temp.
60 mins.
30 mins.
15 mins.
5 mins.
60 mins.
30 mins.
15 mins.
5 mins.
Start
Heating
Compressor
outdoor fan
Set temp.
ON
Compres-
OFF
sor
outdoor fan
Set temp. -Room temp.
(deg)
Room temp.