FDC-HKX
(d) Drain piping
The drain piping can be directed to the floor or rear sides as follows.
(a) Connect a drain piping to the drain outlet and fix it by use of tigghening band.
(b) Indoor side drain piping must be thermally insulated.
(c) After finishing the drain piping, check the drainage by pouring some water in the drain pan.
19.5.2
Installation of the remote controller (Optional parts)
(1) Selection of installation location
Following locations should be avoided:
(a) Where exposed to direct sunlight
(b) Near the heat source
(c) Highly humid area or where splashed with water
(d) Uneven installation surface
(2) Selection of installation location
Exposed installation
(a) Remove the remote controller case.
● Insert finger nails between the upper (white) and lower
(brown) cases and ply them to open.
882
Up-and-down bend
Trap
Decrine
(b) Remote controller cords can be taken out upward only as
● Cut the remote controller lower case off at the top and thin
section with a nipper, knife or other and remove burrs from
the cut with a file or other.
(c) Secure the remote controller lower case on the wall with 2
Upper case (white)
Lower case (brown)
(d) Connect the remote controller cords with the terminal block.
Bad
Bad
shown below.
(Cord take-out direction)
pieces of wood-screws.
Make sure to align the terminal numbers on the indoor unit
and the remote controller. Polarities are specified on the ter-
minal block so that the unit will not be operated if the cords
are connected improperly.
Terminals: (X) red wire, (Y) white wire, (Z) black wire
Top
Top
Lower case
Bottom