Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 134

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

SCM-HG
(4 room)
(b) Memory flap (Excepted 22, 25models)
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is
started.
Recommendable stopping angle of the flap
¡ Wall mounted type
COOL•DRY
HEAT
(c) Swing flap
Flap moves in upward and downward directions continuously.
¡ Wall mounted type
(5) Comfort timer setting
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in auto mode
operation is selected, the comfort timer starts and determines the starting time of next operation based on the initial value of 15
minutes and the relationship between the room temperature at the setting time (temperature of room temperature sensor) and the
setting temperature. (Max. 60 minutes)
Operation mode
3 < Room temp. – Setting temp.
At cooling
3 < Setting temp. – Room temp.
At heating
Notes (1) At 5 minutes before the timer ON time, operation starts regardless of the temperature of the room temperature sensor (Th1).
(2) This function does not actuate when the operation select switch is set at the dehumidifying as well as the dehumidifying in the auto mode.
However, the operation of item (1) above is performed during the dehumidifying in the auto mode.
(3) During the pleasant reservation operation, both the operation lamp and timer lamp illuminate and the timer lamp goes off after expiration of the timer, ON setting
time.
(Example) Heating
Setting temperature
Room temperature
If the difference (= Setting temperature – Room temperature) is 4ºC, the correction value is found to be +5 minutes from the
¡
table shown above so that the starting time of next operation is determined as follows:
15 min. earlier + 5 min. = 20 min. earlier
Current operation
start time
132
Horizontal
blowing
Slant forward
blowing
Operation start time correction value (Min.)
1 < Room temp. – Setting temp. 3
+5
2 < Setting temp. – Room temp. 3
+5
Operation starting time
Time
15 min.
10 min.
5 min.
earlier
earlier
earlier
Correction value
¡ Ceiling recessed type
Horizontal
COOL•DRY
blowing
Slant forward
HEAT
blowing
¡ Ceiling recessed type
Room temp. – Setting temp. 1
No change
Setting temp. – Room temp. 2
No change
Corrects the starting time of next operation by
calculating the temperature difference.
Setting time
–5
–5