Model FDFL308HEN-SA
Item
Nominal cooling capacity
(1)
(1)
Nominal heating capacity
Power source
Cooling input
Running current (Cooling)
Power factor (Cooling)
Heating input
Running current (Heating)
Power factor (Heating)
Inrush current
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
High pressure control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow (Standard)
Fresh air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
fan motor.
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 220/240V 50Hz.
Model
FDFL308-A
W
W
kW
A
%
kW
A
%
A
dB(A)
Hi: 45
(650 + 50) × 1260 × 184
mm
kg
33
kW
Louver fines & inner grooved tubing
kg
Holding charged
r
Multiblade centrifugal fan × 4
35 × 2
W
Line starting
CMM
Hi: 16.5
Not possible
Polypropylene net × 2 (Washable)
Rubber sleeve (for fan motor)
W
Wired remote control switch
(Optional : RCD-H-E)
Thermostat by electronics
Internal thermostat for fan motor.
Frost protection thermostat.
mm
Liquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")
(in)
(Connectable with VP20)
Indoor air temperature
DB
WB
27˚C
19˚C
20˚C
FDFL308HEN-SA
7100
8000
1 Phase, 220/240V, 50Hz
2.99/3.19
13.9/14.4
98/92
2.85/3.01
13.3/13.7
97/92
95
Lo: 39
GT-A5534EN41 × 1
Slitted fins & bare tubing
Capillary tube
R22
1.4 [Pre-charged up to the piping length of 5m]
1.45 [BARREL FREEZE32SAM]
MC controlled de-icer
High pressure switch
Lo: 11.5
Rubber mount (for compressor)
40 (Crank case heater)
Internal thermostat for fan
Abnormal discharge temperature protection.
Flare piping
Necessary (both Liquid & Gas lines)
Mounting kit.
Outdoor air temperature
DB
WB
35˚C
24˚C
7˚C
6˚C
FDFL-H
FDC308HEN3
52
845× 880 × 340
74
2.5
Line starting
Propeller fan × 1
55 × 1
Line starting
58
– (Indoor unit side)
motor.hermostat for
Standards
ISO-T1, JIS B8616