Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 329

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

(b) Operation control function by the wired remote controller
(i)
The following is the sequence of operation for the remote controller operation mode switch.
(ii) CPU reset
This functions when the " inspection " and " filter reset switch " on the remote controller are pushed simultaneously. It
operates in the same manner as the power reset.
(iii) Power outage compensation function.
¡ This is enabled by setting dip switch SW3 on the remote control circuit board to ON.
¡ It records the normally used remote control modes. Once power has been restored, it restarts operation by using the
contents of the memory. Note that the stop positions for auto swing and the timer mode are cancelled.
Parts layout on the remote controller PCB
TEMP DISP.
J1
• Function of DIP switched
Switch
ON
SW
1
OFF
ON
SW
2
OFF
ON
SW
3
OFF
DRY
COOL
Z
Y
X
BLACK
WHITE
RED
R4
Q3
R7
R28
Q1
Q2
FAN SPEED
TIMER FUNC.
J2
Jumper wires (J1 ~ J4)
Function
Cooling only type
Heat pump type
Remote control sensor - Enabled
Remote control sensor - Disabled
Power outage compensation - ON
Power outage compensation - OFF
FAN
HEAT
AUTO
R18
IC1
SWING
DISP.
J3
J4
• Function of Jumper wires
Switch
Wich
J1
(1)
None
Wich
J2
(1)
None
Wich
J3
(1)
None
Wich
J4
(1)
None
Note (1) 'None' means that jumper wire is not provided
on the PCB or the connection ic cut.
FDT ( N ) -H
TYPE
SW1
REMOTE
THERMO
SW2
DIP switched
(SW1 ~ SW4)
POWEP OFF
GUARAMTY
SW3
Function
Inlet temperature display - Enabled
Inlet temperature display - Disabled
Fan display - 3 speeds
Fan display - 2 speeds
Timer function - Enabled (Normal)
Timer function - Disabled
Auto swing display - ON
Auto swing display - OFF
327