Figure 57: Removing A Flex Ioc - Juniper SRX 5600 Hardware Manual

Services gateway
Hide thumbs Also See for SRX 5600:
Table of Contents

Advertisement

SRX 5600 Services Gateway Hardware Guide
CAUTION: The weight of the flex IOC is concentrated in the back end. Be prepared
to accept the full weight—up to 13.1 lb (5.9 kg)—as you slide the flex IOC out of the
chassis.
When the flex IOC is out of the chassis, do not hold it by the ejector handles, bus
bars, or edge connectors. They cannot support its weight.
Do not stack flex IOCs on top of one another after removal. Place each one individually
in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
8.
CAUTION: After removing an IOC from the chassis, wait at least 30 seconds before
reinserting it, removing an IOC from a different slot, or inserting an IOC into a
different slot.

Figure 57: Removing a Flex IOC

Flex IOC
122
Replacing Flex IOCs and Port Modules
If you are not reinstalling a replacement card into the empty slot within a short
time, install a blank panel over the slot to maintain proper airflow in the card
cage.