SRX 5600 Services Gateway Hardware Guide
If a power supply is not functioning normally, perform the following steps to diagnose
and correct the problem:
NOTE: If the system temperature exceeds the threshold, the JUNOS software shuts
down all power supplies so that no status is displayed.
The JUNOS software also can shut down one of the power supplies for other reasons.
In this case, the remaining power supplies provide power to the services gateway,
and you can still view the system status through the CLI or display.
98
Troubleshooting the Power System
and functioning normally, the
steadily.
For more information about the LEDs, see "AC Power Supply LEDs" on page 29
or "DC Power Supply LEDs" on page 31.
Issue the CLI
show chassis environment pem
installed power supplies. As shown in the sample output, the value
rows labeled
State
indicates that the power supplies in slots
functioning normally:
user@host> show chassis environment pem
PEM 0 status:
State
OK
State
OK
DC output
If a red alarm condition occurs, issue the
determine the source of the problem.
Check that the DC circuit breaker
receiving power.
Verify that the source circuit breaker has the proper current rating. Each power
supply must be connected to a separate source circuit breaker.
Verify that the AC power cord or DC power cables from the power source to the
device are not damaged. If the insulation is cracked or broken, immediately
replace the cord or cable.
Connect the power supply to a different power source with a new power cord
or power cables. If the power supply status LEDs indicate that the power supply
is not functioning normally, the power supply is the source of the problem.
Replace the power supply with a spare, as described in "Replacing Power System
Components" on page 133.
If you cannot determine the cause of the problem or need additional assistance,
see "Juniper Networks Technical Assistance Center" on page 93.
,
, and
PWR OK
BRKR ON
command to check the status of
DC output
Online
Temperature
OK
show chassis alarms
or AC switch
is in the on position and is
--
|
LEDs light green
INPUT OK
in the
Online
0
and
1
are
Online
Temperature
OK PEM 1 status:
command to