Figure 58: Installing A Flex Ioc - Juniper SRX 5600 Hardware Manual

Services gateway
Hide thumbs Also See for SRX 5600:
Table of Contents

Advertisement

Installing a Flex IOC
NOTE: Your services gateway must be running JUNOS version 9.5R1 or later in order
to recognize flex IOCs and port modules.
To install a flex IOC (see Figure 58 on page 123):
1.
2.
3.
4.
5.
6.
7.

Figure 58: Installing a Flex IOC

Flex IOC
8.
9.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see "Preventing Electrostatic Discharge Damage" on page 152.
Place the flex IOC on an antistatic mat or remove it from its electrostatic bag.
Identify the slot on the services gateway where you will install the flex IOC.
If you have not already done so, remove the blank panel from the slot where
you are installing the flex IOC.
Orient the flex IOC so that the faceplate faces you.
Lift the flex IOC into place and carefully align the sides of the card with the guides
inside the card cage.
Slide the flex IOC all the way into the card cage until you feel resistance.
Grasp both ejector handles and rotate them clockwise simultaneously until the
flex IOC is fully seated.
Use one of the following methods to bring the flex IOC online:
Press and hold the corresponding online button on the craft interface until
the green
LED next to the button lights steadily, in about 5 seconds.
OK
Issue the following CLI command:
user@host>request chassis fpc slot slot-number online
Chapter 13: Replacing Hardware Components
Replacing Flex IOCs and Port Modules
123

Advertisement

Table of Contents
loading

Table of Contents