SRX 5600 Services Gateway Hardware Guide
8.
9.
10.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of
fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a
transceiver emit laser light that can damage your eyes.
11.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow
fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc
smaller than a few inches in diameter can damage the cable and cause problems
that are difficult to diagnose.
12.
13.
130
Replacing SPCs
Slide the SPC all the way into the card cage until you feel resistance.
Grasp both ejector handles and rotate them clockwise simultaneously until the
SPC is fully seated.
If the SPC uses fiber-optic cable, remove the rubber safety cap from each
transceiver and cable.
Insert the appropriate cables into the cable connector ports on each SPC (see
Figure 63 on page 131). Secure the cables so that they are not supporting their
own weight. Place excess cable out of the way in a neatly coiled loop, using the
cable management system. Placing fasteners on a loop helps to maintain its
shape.
Power on the services gateway as described in "Powering On an AC-Powered
Services Gateway" on page 65 or "Powering On a DC-Powered Services Gateway"
on page 68. The
OK
LED on the power supply faceplate should blink, then light
steadily.
Verify that the SPC is functioning correctly by issuing the
show chassis fpc pic-status
SPCs" on page 84 and "Maintaining IOC Cables" on page 85.
commands, as described in "Maintaining IOCs and
and
show chassis fpc