Installing the Mounting Hardware

Installing the Mounting Hardware for a Rack or Cabinet

The services gateway can be installed in a four-post rack or cabinet or an open-frame
rack. Install the mounting hardware on the rack before installing the device.
After the mounting hardware is installed, proceed to "Installing the Services Gateway"
on page 53 or "Installing the Services Gateway Without a Mechanical Lift" on page
201, depending on your type of installation.
This chapter describes the procedures for installing the mounting hardware:
Installing the Mounting Hardware for a Rack or Cabinet on page 49
Removing the Mounting Brackets for Center-Mounting the Device on page 51
Install the mounting shelf, which is included in the shipping container, before installing
the device. We recommend that you install the mounting shelf because the weight
of a fully loaded device can be up to 163.5 lb (74.2 kg).
Table 25 on page 49 specifies the holes in which you insert cage nuts and screws to
install the mounting hardware required (an X indicates a mounting hole location).
The hole distances are relative to one of the standard U divisions on the rack. The
bottom of all mounting shelves is at 0.02 in. above a U division.

Table 25: Four-Post Rack or Cabinet Mounting Hole Locations

Hole
Distance Above U Division
4
2.00 in. (5.1 cm)
3
1.51 in. (3.8 cm)
2
0.88 in. (2.2 cm)
1
0.25 in. (0.6 cm)
1.14 U
0.86 U
0.50 U
0.14 U
Installing the Mounting Hardware for a Rack or Cabinet
Mounting Shelf
X
X
X
X
49