SRX 5600 Services Gateway Hardware Guide

Tools Required

To install the services gateway, you need the following tools:

Installing the Services Gateway Using a Lift

Before installing the services gateway in the rack, read the safety information in
"Chassis Lifting Guidelines" on page 154. Remove the device from the shipping
container as described in "Unpacking the Services Gateway" on page 45. Install the
mounting hardware as described in "Installing the Mounting Hardware" on page 49.
CAUTION: Before front mounting the device in a rack, have a qualified technician
verify that the rack is strong enough to support its weight and is adequately supported
at the installation site.
To install the device using a lift (see Figure 28 on page 55):
1.
2.
3.
4.
5.
6.
7.
8.
9.
54
Installing the Services Gateway Using a Mechanical Lift
Mechanical lift
Phillips (+) screwdriver, number 2
Ensure the rack is in its permanent location and is secured to the building. Ensure
that the installation site allows adequate clearance for both airflow and
maintenance. For details, see "Preparing the Site for Services Gateway
Installation" on page 37.
Load the device onto the lift, making sure it rests securely on the lift platform.
Using the lift, position the device in front of the rack or cabinet, centering it in
front of the mounting shelf.
Lift the device approximately 0.75 in. above the surface of the mounting shelf
and position it as close as possible to the shelf.
Carefully slide the device onto the mounting shelf so that the bottom of the
chassis and the mounting shelf overlaps by approximately two inches.
Slide the chassis onto the mounting shelf until the mounting brackets contact
the rack rails. The shelf ensures that the holes in the mounting brackets of the
chassis align with the holes in the rack rails.
Move the lift away from the rack.
Install a mounting screw into each of the open mounting holes aligned with the
rack, starting from the bottom.
Visually inspect the alignment of the device. If the device is installed properly in
the rack, all the mounting screws on one side of the rack should be aligned with
the mounting screws on the opposite side and the device should be level.