9.
NOTE: If more than one power supply is being installed, turn on all power supplies
at the same time.
10.

Figure 70: Connecting Power Cables to the DC Power Supply

Replacing the Cable Management System

Removing the Cable Management System

The cable management system is located on both sides of the card cage. The cable
management system weighs approximately 0.3 lb (0.14 kg).
To remove the cable management system (see Figure 71 on page 144):
1.
Switch the circuit breaker on the power supply to the
Verify that the DC source power cabling is correct. Observe the status of the
LEDs on the power supply faceplate. If the power cable is correctly installed and
the power supply is functioning normally, the
LEDs light green steadily.
Removing the Cable Management System on page 143
Installing the Cable Management System on page 144
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see "Preventing Electrostatic Discharge Damage" on page 152.