Reinstalling the Power Supplies
Reinstall the rightmost power supply first and then work your way to the left. To
reinstall the AC or DC power supplies, follow this procedure for each power supply
(see Figure 82 on page 209, which shows the installation of the DC power supplies):
1.
2.
3.
4.

Figure 82: Reinstalling a Power Supply

Reinstalling the Fan Tray
To reinstall the fan tray, use the following procedure:
1.
Appendix F: Installing the Services Gateway Without a Mechanical Lift
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see "Preventing Electrostatic Discharge Damage" on page 152.
For an AC-powered services gateway, switch the AC switch on the power supply
slot to the off position (
). For a DC-powered services gateway, switch the circuit
O
breaker on the power supply to the
We recommend this even though the power supplies are not connected to power
sources.
Using both hands, slide the power supply straight into the chassis until the power
supply is fully seated in the chassis slot. The power supply faceplate should be
flush with any adjacent power supply faceplate (see Figure 82 on page 209).
Tighten the captive screws.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see "Preventing Electrostatic Discharge Damage" on page 152.