Juniper SRX 5600 Hardware Manual page 108

Services gateway
Hide thumbs Also See for SRX 5600:
Table of Contents

Advertisement

SRX 5600 Services Gateway Hardware Guide
82
Maintaining the Host Subsystem
Check the LEDs on the craft interface to view information about the status of
the Routing Engines. For more information about the LEDs, see "Craft Interface"
on page 23.
Check the LEDs on the SCB faceplate (see Table 11 on page 19).
Check the LEDs on the Routing Engine faceplate (see Table 12 on page 21).
To check the status of the Routing Engine, issue the
command. The output is similar to the following:
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state
Election priority
Temperature
CPU temperature
DRAM
Memory utilization
CPU utilization:
User
Background
Kernel
Interrupt
Idle
Model
Serial ID
Start time
Uptime
Load averages:
To check the status of the SCBs, issue the
The output is similar to the following:
user@host> show chassis environment cb
CB 0 status:
State
Temperature
Power 1
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
12.0 V
1.25 V
3.3 V SM3
5 V RE
12 V RE
Power 2
11.3 V bias PEM
4.6 V bias MidPlane
show chassis routing-engine
Master
Master (default)
36 degrees C / 96 degrees F
33 degrees C / 91 degrees F
2048 MB
12 percent
1 percent
0 percent
4 percent
0 percent
94 percent
RE-S-1300
1000697084
2008-07-11 08:31:44 PDT
3 hours, 27 minutes, 27 seconds
1 minute
5 minute
0.44
0.16
show chassis environment cb
Online Master
40 degrees C / 104 degrees F
1208 mV
1521 mV
1807 mV
2507 mV
3319 mV
5033 mV
12142 mV
1243 mV
3312 mV
5059 mV
11968 mV
11253 mV
4814 mV
15 minute
0.06
command.