Juniper SRX 5600 Hardware Manual page 137

Services gateway
Hide thumbs Also See for SRX 5600:
Table of Contents

Advertisement

Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
1.
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see "Preventing Electrostatic Discharge Damage" on page 152.
Power off the device as described in "Powering Off the Services Gateway" on
2.
page 70.
Carefully align the sides of the SCB with the guides inside the chassis.
3.
Slide the SCB into the chassis until you feel resistance, carefully ensuring that it
4.
is correctly aligned.
Grasp both ejector handles and rotate them simultaneously clockwise until the
5.
SCB is fully seated.
Place the ejector handles in the proper position, vertically and toward the center
6.
of the board.
Power on the services gateway as described in "Powering On an AC-Powered
7.
Services Gateway" on page 65 or "Powering On a DC-Powered Services Gateway"
on page 68. The
OK
LED on the power supply faceplate should blink, then light
steadily.
To verify that the SCB is functioning normally, check the LEDs on its faceplate.
8.
The green
OK/FAIL
LED should light steadily a few minutes after the SCB is
installed. If the
OK/FAIL
"Removing an SCB" on page 110 and "Installing an SCB" on page 110). If the
LED still lights steadily, the SCB is not functioning properly. Contact
OK/FAIL
your customer support representative.
To check the status of the SCB:
user@host> show chassis environment cb
CB 0 status:
State
Temperature
Power 1
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
12.0 V
1.25 V
3.3 V SM3
5.0 V RE
12.0 V RE
Power 2
11.3 V bias PEM
4.6 V bias MidPlane
11.3 V bias FPD
11.3 V bias POE 0
11.3 V bias POE 1
Bus Revision
FPGA Revision
CB 1 status:
State
Temperature
Chapter 13: Replacing Hardware Components
LED is red, remove and install the SCB again (see
Online Master
30 degrees C / 86 degrees F
1202 mV
1511 mV
1798 mV
2481 mV
3306 mV
4956 mV
12084 mV
1250 mV
3287 mV
5046 mV
11910 mV
11292 mV
4833 mV
11156 mV
11253 mV
11272 mV
42
1
Online
31 degrees C / 87 degrees F
Replacing Host Subsystem Components