Nortel 1000 Features And Services Fundamentals page 550

Book 2 of 6 (c)
Table of Contents

Advertisement

550 Collect Call Blocking
Prompt
Response
M911_ANI
NO
...
ISDN
NO
...
ICOG
IAO ICT OGT
...
CNTL
(NO) YES
...
CCB
(NO) YES
CCB1
512-(1536)-4992
CCB2
500-(1520)-2550
CCBA
(NO) YES
LD 14 - Setup the firmware timing for XFCOT and EXUT cards.
Prompt
Response
REQ
NEW
CHG
TYPE
DID COT FEX
WAT
TN
l s c u
c u
XTRK
EXUT
XCOT
Copyright © 1994–2008, Nortel Networks
.
Description
M911 route. Must be set to NO to enable CCB.
ISDN route. Must be set to NO to enable CCB.
Incoming and outgoing, incoming, or outgoing. Must be
either IAO or ICT to enable CCB.
Must be either IAO or OGT to get the CCBA prompt for
outgoing calls.
Change to controls or to timers.
Collect Call Blocking enabled or disabled on incoming
route. CCB package 290 is required. Enter YES to obtain
CCB timer prompts.
Collect Call Blocking delay timer 1 in milliseconds. Input
rounded to the next multiple of 128 milliseconds.
Collect Call Blocking delay timer 2 in milliseconds. Input
rounded to the next multiple of 10 milliseconds. If any CCB
route members (trunks) are using firmware timing (FWTM
= YES in LD 14), changes to the CCB2 timer value will not
take effect until the new timer value is downloaded to the
card. This can be done by enabling the card or initializing
the switch.
Collect Call Blocking allowed or denied for outgoing route.
Description
Add.
Change.
Trunk Type.
Terminal number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
Type of card.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008