Prompt
Response
...
DN
x..x yyyy
(CNUD)
CNUA
CNUS
(CNAD)
CNAA
CLS
...
LD 13 - Configure the CLASS modem unit (up to 255 CLASS modem units may be configured
per system).
Prompt
Response
REQ
NEW
CHG
TYPE
CMOD
1-127
DMOD
TN
l s c u
c u
While no new License limit is introduced by the CLASS feature, each
CLASS modem unit TN is counted against the system TN limit and is
reflected in the overlay banner.
You can print the CMOD unit information using LD 20.
Copyright © 1994–2008, Nortel Networks
.
Description
Directory Number for this set (x..x) and CLID entry associated
with this set (ENTRY configured in LD 15).
CLASS Calling Number Delivery Denied.
CLASS Calling Number Multiple Data Format Allowed.
CLASS Calling Number Single Data Format Allowed.
CLASS Calling Name Delivery Denied.
CLASS Calling Name Multiple Data Format Allowed.
Refer to the section
sets" (page 496)
These Class of Service entries are not valid for a Dial Intercom
Group (DIG) set
Description
Add new data
Change existing data.
CLASS modem unit.
Default Model number for this route for Small System and Media
Gateway 1000B.
Terminal number
Note: Since the CLASS modem unit uses the octal-density
Extended CLASS Modem Card (XCMC), up to 32 units can be
configured on any XCMC card.
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
Format for Small System and Media Gateway 1000B where c =
card and u = unit.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Feature implementation 521
"Configure CND Class of Service on CLASS
for details.

Advertisement