Nortel 1000 Features And Services Fundamentals page 308

Book 2 of 6 (c)
Table of Contents

Advertisement

308 Called Party Control on Internal Calls
LD 10 - Enable Malicious Call Trace on Analog (500/2500 type) sets.
Prompt
Response
REQ:
NEW
CHG
TYPE:
500
TN
l s c u
c u
xx
CUST
...
CLS
MCTA
LD 11 - Enable Malicious Call Trace on Meridian 1 proprietary sets.
Prompt
Response
REQ:
NEW
CHG
a...a
TYPE:
TN
l s c u
c u
xx
CUST
...
CLS
MCTA
KEY
xxx TRC
For information on the implementation of the Malicious Call Trace feature,
refer to the Malicious Call Trace feature description in Features and Services
Fundamentals (NN43001-106), Book 2.
Feature operation
Feature operation is described in the following scenarios.
Copyright © 1994–2008, Nortel Networks
.
Description
Add new data.
Change existing data.
Analog Set Type.
Terminal number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
Format for Small System and Media Gateway 1000B where c =
card and u = unit.
Customer number, as defined in LD 15
Malicious Call Trace allowed.
MCTD = Malicious Call Trace denied.
Description
Add new data.
Change existing data.
Telephone type. Type ? for a list of possible responses.
Terminal number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
Format for Small System and Media Gateway 1000B where c =
card and u = unit.
Customer number, as defined in LD 15
Malicious Call Trace allowed.
MCTD = Malicious Call Trace denied.
Key Number, Malicious Call Trace.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008