Nortel 1000 Features And Services Fundamentals page 184

Book 2 of 6 (c)
Table of Contents

Advertisement

184 Call Forward, Remote (Attendant and Network Wide)
LD 12 - Configure the attendant console RFW key.
Prompt
Response
REQ
NEW
CHG
TYPE
2250
TN
l s c u
c u
...
KEY
xx RFW
LD 15 - Configure the Attendant RCFW password.
Prompt
Response
REQ:
CHG
TYPE:
ATT_DATA
CUST
0-99
0-31
...
- IRFR
(NO) YES
xxxxxxxx
- - IRFP
- XRFR
(NO) YES
- XRFP
xxxxxxxx
Copyright © 1994–2008, Nortel Networks
.
Description
Add new data.
Change existing data.
Attendant console type.
Terminal number
Format for Large System and CS 1000E system, where l = loop,
s = shelf, c = card, u = unit.
Format for Small System and Media Gateway 1000B where c =
card and u = unit.
Key number assigned as Attendant Remote Call Forward key.
Description
Change existing data.
Attendant console options
Customer number
Range for Large System and CS 1000E system.
Range for Small System and Media Gateway 1000B.
Internal Remote Call Forward Password required.
An internal password is the password required to perform an
attendant RCFW operation within the same customer as the
attendant.
Internal RCFW Password (only prompted if the response to
IRFR is YES).
The password length is one to eight digits; the password is
numeric only.
External Remote Call Forward Password required.
An external password is the password required to perform an
attendant RCFW operation on a different customer than the
attendant.
External RCFW password (only prompted if the response to
XRFR is YES).
The password length is one to eight digits; the password is
numeric only.