Nortel 1000 Features And Services Fundamentals page 318

Book 2 of 6 (c)
Table of Contents

Advertisement

318 Calling Party Name Display Denied
a QSIG network is interacting with an Meridian Customer Defined Network
(MCDN) network providing network capability ND3, both the MCDN and
QSIG Name Display feature function on the same level.
Multiple Appearance Directory Numbers
For a ringing call to a Multiple Appearance Directory Number (DN), the
name on the calling set display can be suppressed by configuring any of
the Terminal Numbers with NAMD Class of Service. The digit display on
the calling set cannot be suppressed—the called digits are displayed even
though the Class of Service on any of the Terminal Numbers is DIGD.
The called set display is subject to the Class of Service of the calling
party. For an established call to a Multiple Appearance Directory Number
(DN), the calling set display is subject to the Class of Service configured
for the answering set. The answering set display only is subject to the
Class of Service of the calling party—the displays of the other sets in the
Multiple-appearance group are blank.
Office Data Administration System (ODAS)
Depending on the Class of Service of the originating set, the ODAS
designator is displayed or replaced by Xs, up to the maximum number of
characters that the designator may have.
Feature packaging
Calling Party Name Display Denied requires International Supplementary
Features (SUPP) package 131.
Feature implementation
Task summary list
The following is a summary of the tasks in this section:
1.
2.
LD 10 - Configure the Calling Party Name Denied Class of Service for analog (500/2500 type)
telephones.
Prompt
Response
REQ:
NEW
CHG
Copyright © 1994–2008, Nortel Networks
.
"LD 10 - Configure the Calling Party Name Denied Class of Service for
analog (500/2500 type) telephon" (page 318)
Configure the Calling Party Name Denied Class of Service for analog
(500/2500 type) telephones.
"LD 11 - Configure the Calling Party Name Display Denied Class of
Service for proprietary telephones." (page 319)
Configure the Calling Party Name Display Denied Class of Service for
proprietary telephones.
Description
Add new data.
Change existing data.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard