AT&T SB67030 Administrator's Manual page 251

Hide thumbs Also See for SB67030:
Table of Contents

Advertisement

Symptom
Overhead paging (OHP) is
not working. (Continued)
I cannot add a multi-zone
paging zone to other paging
zones.
Unable to make phone calls
on the extension configured
for the FXS OHP jack.
Troubleshooting
Synapse Administrator's Guide
Probable Cause
The OHP may not be properly
installed.
Multi-zone paging does not
allow a combination of OHP
equipment and Desksets
within one paging zone.
System limitation.
Corrective Action
For OHP equipment connected to an FXS port, verify
WebUI configuration:
a.
Connect a corded phone to the FXS port configured
for paging and verify that the phone rings when it is
paged.
b. If the phone does not ring, there is a problem with the
WebUI configuration or the installation at the ATA.
c.
If the phone rings, the configuration allows
communication with the OHP. Verify your paging
equipment. Does it have power? Is it turned on?
Refer to your paging equipment documentation if
there are still problems.
Page multi-zone OHP zones separately from extensions.
Once an FXS is configured for OHP, it cannot be used for
audio calls, nor will it receive voice calls.