<Sysname> system-view
[Sysname] mld
[Sysname-mld] startup-query-interval 5

timer other-querier-present (MLD view)

Syntax
timer other-querier-present interval
undo timer other-querier-present
View
MLD view
Default Level
2: System level
Parameters
interval: MLD other querier present interval in seconds, in the range of 60 to 300.
Description
Use the timer other-querier-present command to configure the MLD other querier present interval
globally.
Use the undo timer other-querier-present command to restore the default configuration.
By default, MLD other querier present interval = [ MLD query interval ] times [ MLD querier robustness
variable ] plus [ maximum response delay for MLD general queries ] divided by two.
By default, the values of the three parameters in the above-mentioned formula are 125, 2, and 10,
respectively, so the MLD other querier present interval is 125 x 2 + 10 / 2 = 255 (seconds).
Related
commands:
max-response-time, display mld interface.
Examples
# Set the MLD other querier present interval to 200 seconds globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] timer other-querier-present 200

timer query (MLD view)

Syntax
timer query interval
mld
timer
other-querier-present,
1-28
timer
query,
robust-count,