Igmp-Snooping Host-Aging-Time - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Use the undo igmp-snooping group-policy command to remove a multicast group filter on the
current port(s).
By default, no multicast group filter is configured on an interface, namely a host can join any valid
multicast group.
Note that:
If you do not specify any VLAN when using this command in Ethernet interface view or Layer 2
aggregate interface view, the command will take effect for all VLANs the interface belongs to; if you
specify a VLAN or multiple VLANs, the command will take effect only if the interface belongs to the
specified VLAN(s).
If you do not specify any VLAN when using this command in port group view, the command will
take effect on all the ports in this group; if you specify a VLAN or multiple VLANs, the command will
take effect only on those ports in this group that belong to the specified VLAN(s).
If the specified ACL does not exist or the ACL rule is null, all multicast groups will be filtered out.
You can configure different ACL rules for a port in different VLANs; for a given VLAN, a newly
configured ACL rule will override the existing one.
Related commands: group-policy.
Examples
# Apply ACL 2000 as a multicast group filter on Ethernet 2/0/1 in VLAN 2.
<Sysname> system-view
[Sysname] interface ethernet 2/0/1
[Sysname-Ethernet2/0/1] igmp-snooping group-policy 2000 vlan 2

igmp-snooping host-aging-time

Syntax
igmp-snooping host-aging-time interval
undo igmp-snooping host-aging-time
View
VLAN view
Default Level
2: System level
Parameters
interval: Dynamic member port aging time, in seconds. The effective range is 200 to 1,000.
Description
Use the igmp-snooping host-aging-time command to configure the aging time of dynamic member
ports in the current VLAN.
Use the undo igmp-snooping host-aging-time command to restore the default setting.
By default, the aging time of dynamic member ports is 260 seconds.
This command takes effect only if IGMP Snooping is enabled in the VLAN.
Related commands: igmp-snooping enable , host-aging-time.
1-13

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

S7910eS7906e-vS7903eS7903e-sS7902e

Table of Contents