Graceful-Restart Timer Wait-For-Rib - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Parameters
timer: Maximum time for a peer to reestablish a BGP session, in the range 3 to 600 seconds.
Description
Use the graceful-restart timer restart command to configure the maximum time for a peer to
reestablish a BGP session.
Use the undo graceful-restart timer restart command to restore the default.
By default, the maximum time for a peer to reestablish a BGP session is 150 seconds.
Examples
# Configure the maximum time for a peer to reestablish a BGP session as 300 seconds.
<Sysname> system-view
[Sysname] bgp 100
[Sysname-bgp] graceful-restart timer restart 300

graceful-restart timer wait-for-rib

Syntax
graceful-restart timer wait-for-rib timer
undo graceful-restart timer wait-for-rib
View
BGP view
Default Level
2: System level
Parameters
timer: Time to wait for the End-of-RIB marker, in the range 3 to 300 seconds.
Description
Use the graceful-restart timer wait-for-rib command to configure the time to wait for the End-of-RIB
marker.
Use the undo graceful-restart timer wait-for-rib command to restore the default.
By default, the time to wait for the End-of-RIB marker is 180 seconds.
After a BGP session has been successfully (re)established, the End-of-RIB marker must be
received within the time specified with this command.
Using this command can speed up route convergence.