Selecting Inclination Compensation Error Handing - Omron Z550 Operation Manual

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Selecting Inclination Compensation Error Handing

This function is only valid when Inclination compensation has been specified.
Select whether or not to treat the measurement result as an error when it is not possible to measure the
reference height of a region.
Measurement
Option
of reference
height
Inactive
OK
NG
Active
OK
NG
[Slant error] cannot be specified for [Define].Errors are handled according to the [Slant error] settings
specified for the other outputs set in the defining equation.
1.
Select [Meas set].
The selections for output appear.
2.
Move the cursor to the output to be set and press
the ENT Key.
Setting Measurement Conditions (Expert Menu)
Measurement processing
The measurement is made after
inclination compensation.
The measurement is made
without performing inclination
compensation.
Make the measurement after
inclination compensation.
The measurement is not made.
Judgment
Judgment and output are performed according to
the measurement result.
Judgment and output are performed according to
the measurement result.
Judgment and output are performed according to
the measurement result.
Judgment and output will result in an error.
Scn 0
Set
Image
Detect set
Meas set
Extra set
Meas mode
Output
Scn 0
Set
OUT0:Height
OUT1:Step: 2 pts
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7:
SECTION 3
Z550
113
Operation Manual