Omron Z550 Operation Manual page 229

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Timing Chart 6
Measurement mode
Trigger measurement
(External)
Images for the set measurement time are obtained from the TRG signal input of the terminal
block and hold measurement is performed.
Assuming the measurement duration is specified to three times the measurement time (*1)
OFF
TRG
ON
of terminal block
OFF
Measurement time
ON
(internal signal)
Measurement time
Image acquisition
Calculation
processing
Terminal block output (*2)
Analog output
(OUT for which hold is set)
Terminal block output
Analog output
(OUT for which no hold is set)
OFF
GATE output
ON
PROFILE data
(sent by Controller)
RUN output OFF
ON
BUSY output OFF
ON
*1 Specify the measurement duration to 200 ms when the measurement time is 100 ms in order to set it
to three times the measurement time.
*2 ALL-PASS and ERROR outputs are always output at the timing when "hold" is set.
Communication with External Devices
Hold&Logging
Hold (External)
SECTION 6
Output value according to the hold setting
GATE
GATE
ON time
ON delay
Operation Manual
Z550
227