Timing Chart 12
Measurement mode
Trigger measurement
(RS-232C)
Measurement is performed according to the CAPTURE command of the RS-232C, and
measurement values are accumulated and output according to the specified logging conditions.
When the hold conditions are specified, the corresponding values are held, accumulated, and
then output.
Assuming the sampling interval is set to three samples
CAPTURE
command
(received by Controller)
Image acquisition
Calculation
processing
Accumulated data
(OUT for which hold is set)
Terminal block output
Analog output
(OUT for which hold is set)
Accumulated data
(OUT for which no hold is set)
Terminal block output (*1)
Analog output
(OUT for which no hold is set)
OFF
GATE output
ON
(*2)
PROFILE data
(sent by Controller)
RUN output OFF
ON
BUSY output OFF
ON
*1 ALL-PASS and ERROR outputs are always output at the timing of "no hold" is set.
*2 The GATE output does not function at logging.
Hold&Logging
Logging
Measurement time
Communication with External Devices
Accumulate values according to the hold setting.
Output value according to the hold setting
Accumulate data once every three measurements
SECTION 6
Z550
233
Operation Manual