Number of Interpolated Pixels
Profile data is interpolated only if missing areas (areas where measurement data cannot be
obtained) contain less than the specified number of pixels. Interpolation is not performed if a
greater number of pixels than the specified number cannot be measured continuously.
This function can be applied to the measurement of a workpiece with a hole.Select [ALL] to
always interpolate between the existing data regardless of the number of pixels.
1 pixel, 2 pixels, 4 pixels, 8 pixels, 16 pixels, ALL (default setting)
Example: When the number of interpolated pixels is 2
Not interpolated
(3pixel>2pixel)
Edge Detection Hysteresis Width (Edge Width)
The hysteresis width of edge detection can be set.
Change the edge width when the edge detection is unstable.
0.000000 to 999.999999 (0.000000 is set by default setting)
Example: When the level is 80.0000 mm and the level hysteresis width is 0.0500 mm
Setting Measurement Conditions (Expert Menu)
Option
Areas where measurement
values could not be obtained
Height
direction
Interpolate
(1pixel
Setting range
Hysteresis 0.0500
Level
80.0000
Edge position
Position
direction
2pixel)
SECTION 3
Z550
131
Operation Manual