Omron Z550 Operation Manual page 197

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Item
Option
Format
Command
(Default setting)
Trigger OFF
Data
Measurement
(Default setting)
Result
Measmt + Result
Output #
OUT0 to OUT7
(Set to OUT0 by
default setting)
Consecutive
Communication with External Devices
Measurement data is output only when a data acquisition command
(e.g., MEASURE or JUDGE) is input from an external device.
When hold output or logging output is used, the measurement data is
output after the profile data is output. It is not necessary to enter a
data acquisition command (e.g., MEASURE or JUDGE).
Measurement values are output to RS-232C.The output method is the
same as for the MEASURE command.
Judgment results (HIGH/PASS/LOW/ERROR) are output to RS-
232C.The output method is the same as for the JUDGE command.
The judgment result is output first, followed by the measurement
value.
Select the output (OUT0 to OUT7) whose data is to be output.
When [Consecutive] is selected, the data of OUT0 through OUT7 will
be output continuously in series.
SECTION 6
Meaning
Operation Manual
Z550
195