Omron Z550 Operation Manual page 225

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Timing Chart 2
Measurement mode
Continuous measurement
Hold measurement is performed at the timing when the TRG signal of the terminal block is input
during a continuous measurement.
Assuming the measurement duration is specified to three times the measurement time (*1)
OFF
TRG of
ON
terminal block
OFF
Measurement time
ON
(internal signal)
Measurement time
Image acquisition
Calculation processing
Terminal block output (*2)
Analog output
(OUT for which hold is set)
Terminal block output
Analog output
(OUT for which no hold is set)
OFF
GATE output
ON
PROFILE command
(received by Controller)
PROFILE data
(sent by Controller)
OFF
RUN output
ON
OFF
BUSY output
ON
*1 Specify the measurement duration to 200 ms when the measurement time is 100 ms in order to set it
to three times the measurement time.
*2 ALL-PASS and ERROR outputs are always output at the timing when "hold" is set.
*3 Profile data for which arithmetic processing has been completed when the PROFILE command is
received is transmitted.
Communication with External Devices
Hold&Logging
Hold (External)
Output value according to the hold setting
GATE
ON delay
PROFILE command
SECTION 6
GATE
ON time
PROFILE data(*3)
Operation Manual
Z550
223