Omron Z550 Operation Manual page 29

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Line Brightness Display
This display allows checking the line beam image and the brightness information for each line
(line brightness).
• At setting: It is possible to check whether sensitivity is appropriate.
• During measurement: It helps analyzing factors when an error occurs.
Line Brightness (Brightness Distribution) (Yellow)
The line brightness graph at the cursor position is displayed.
It is possible to know at a glance whether or not, for example,
the light density is insufficient, or is at the saturation level.
This indicates the brightness of each line; move the cursor to
check brightness of other lines.
Scn 0
NEAR
FAR
How to change the cursor position p.144
Common Display
Items commonly displayed in both the profile and line brightness displays are explained below.
Scn 0
Output number
(OUT 0 to OUT 7)
The output number
for the currently
displayed
measurement result
OUT 0
is displayed.
+005.188000
Measurement value
S+ / :Display S+ENT:Adjust
The measurement
value is displayed
Judgment results
in green if the judgment
HIGH : Greater than the judgment upper limit
result is PASS.
PASS : Within the judgment limits
It is displayed in red
LOW : Less than the judgment lower limit
if the judgment result
ERROR : Measurement error
is HIGH, LOW,
or ERROR.
RESET: No-measurement state
LD-OFF: LD-OFF input
Line Brightness Cursor (Red)
Run
99.60ms
Sen0
[ 15]
LV
[ 170]
PEAK
Sen1
[
LV
[
PEAK
DARK
BRIGHT
Brightness
Bright
Dark
Run
99.60ms
Sen0
[ 15]
LV
[ 170]
PEAK
Sen1
LV
PEAK
Zero's OFF
mm
PASS
-The workpiece is out of the measurement range
-The light density is insufficient
-Information on the measurement point cannot
be obtained, or other cases
]
Line beam image
]
The shape of workpieces and
the way they are detected
can be checked.
LV: Displays current sensitivity level. (1 to 31)
The value increases with increase in darkness of
the workpiece, while it decreases with increase
[
]
in brightness of the workpiece.
[
]
PEAK: Displays current received level.
Use this value as reference when setting
the sensitivity level.
120 max.: Insufficient light density
255 min.: Excessive light density
Forced-zero
Zero's OFF: Forced-zero not executed
Zero's ON: Forced-zero executed
SECTION 2
Basic Operations
Z550
Operation Manual
27

Advertisement

Table of Contents
loading

Table of Contents