SECTION 2
Basic Operations
5
Setting Workpiece Position Detection Method
Step
Use the detection function if it is anticipated that the position of the workpiece may be shifted.
This function supports shifts in the position in the height and horizontal directions, and the inclination.
Example: Measuring the gap between two locations
No position shift
(the same position
as at the setting)
When the position shifts
Z550
38
Operation Manual
Sensor
Scn 0
Measurement target lines
Accurate measurement cannot be performed.
Scn 0
By setting position compensation...
The measurement target lines are automatically adjusted by
the amount of shift detected, and the measurement is performed.
Scn 0
Run
Run
Run
Measurement target lines
High
Height
Low