Cross-sectional area
The cross-sectional area of the workpiece can be measured.
Specify the bottom face. The cross-sectional area is calculated by integrating the distances
between each of the measurement points and the bottom face.
The following conditions will be used as an example for describing the setting procedures.
1.
Select [Meas set].
A list of outputs appears.
2.
Select an output for which [Area] is set.
In this example, select [OUT1].
Setting Measurement Conditions (Expert Menu)
Cross-sectional
area
Bottom
Bottom
face 1
face 2
Scn 0
Image
Detect set
Meas set
Extra set
Meas mode
Output
Scn 0
OUT0:Height
OUT1:
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7: