Omron Z550 Operation Manual page 31

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Trend Display
The measurement value at the trend cursor position is displayed in a time series.
Press the TRIG Key to switch between display update and stop.It is also possible to specify the
timing via an external trigger.
Trend Cursor
Scn 0
Run
1div T: 0.996 [s]
V:0.1250[mm]
How to change the cursor position p.155
Other Display Items
Thru
Sen 0
+005.188000
Measurement
value
Sensor number
The current sensor number is displayed.
(Sen 0, Sen 1)
High
Low
Time(s)
Waveform display status
During waveform display,
While the waveform is stopped,
Conversion values for X and Y axes
The units corresponding to 1 division (1 div) on the
waveform display are displayed. If the setting is
changed, the display also changes. Use these values
as reference when displaying the waveform.
1div
T:Second(s)
V:Measurement value(mm)
Screen Mode
Thru: The waveform is displayed continuously.
99.60ms
Trig: The waveform is updated when
mm
PASS
Judgment result
Basic Operations
(green) is displayed.
(red) is displayed.
the trigger turns ON.
SECTION 2
Z550
29
Operation Manual