Omron Z550 Operation Manual page 231

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Timing Chart 8
Measurement mode
Trigger measurement
(External)
Measurement is performed according to the TRG signal of the terminal block, and measurement
values are accumulated and output according to the specified logging conditions. When the hold
conditions are specified, the corresponding values are held, accumulated, and then output.
Assuming the sampling interval is set to three samples
OFF
TRG
ON
of terminal block
Image acquisition
Calculation
processing
Accumulated data
(OUT for which hold is set)
Terminal block output
Analog output
(OUT for which hold is set)
Accumulated data
(OUT for which no hold is set)
Terminal block output (*1)
Analog output
(OUT for which no hold is set)
OFF
GATE output
ON
(*2)
PROFILE data
(sent by Controller)
RUN output OFF
ON
BUSY output OFF
ON
*1 ALL-PASS and ERROR outputs are always output at the timing when "no hold" is set.
*2 The GATE output does not function at logging.
Hold&Logging
Logging
Measurement
time
Communication with External Devices
Accumulate values according to the hold setting.
Output value according to the hold setting
Accumulate data once every three measurements
SECTION 6
Z550
229
Operation Manual