SECTION 3
Setting Measurement Conditions (Expert Menu)

Setting Measurement Items

Up to eight measurement items can be set for each scene.
The Controller provides 12 measurement items, each of which can be assigned to outputs OUT0 to
OUT7.In other words, it is possible to perform up to eight measurements simultaneously.
[Height] is set in OUT0 as the default setting at shipment.
Measurement item
Height

Step: 2 pts

Step: 3 pts

Edge position

Width

Edge center

Peak/bottom

Z550
70
Operation Manual
Meaning
The height is measured within the specified region.
Two target measurement lines are specified.
After taking the measurement point on the 1st line as
the reference, the distance from the measurement
point on the 2nd line is measured.
Three target measurement lines are specified.
After taking the average of the measurement points
on two of the lines specified above, the difference
from the measurement point on the 3rd line is
measured.
The specified edge position is measured.
The difference between the specified two edge
positions is measured.
The center is measured based on the specified two
edge positions.
The peak or bottom point of the height within the
specified measurement target line is measured.
Explanatory
Reference
diagram
p.72
p.74
p.75
p.78
p.81
p.84
p.85

Advertisement