Digital Monitor; Step: 2 Pts; Width - Omron Z550 Operation Manual

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

SECTION 2
Basic Operations

Digital Monitor

This monitor screen is mostly used during line operation.
Two or more measurement results that have been set for the output numbers of the displayed
scenes appear.
Scn 0
0
1
2
3
S+ / :Display S+ENT:Adjust
Scn 0
4
5
6
7
S+ / :Display S+ENT:Adjust
The measurement items can also be displayed instead of the judgment values.
Scn 0
0
1
2
3
S+ / :Display S+ENT:Adjust
Z550
30
Operation Manual
Output number
Press the TRIG Key to switch the number.
Run
+002.654132mm
HI=+010.000000
PASS
LO=-010.000000
+004.654321mm
HI=+010.000000
PASS
LO=-010.000000
-----------------mm
HI=+010.000000
ERROR
LO=-010.000000
-----------------mm
HI=+010.000000
LO=-010.000000
TRIG Key
TRIG Key
Run
+002.654132mm
HI=+010.000000
PASS
LO=-010.000000
+004.654321mm
HI=+010.000000
PASS
LO=-010.000000
-----------------mm
HI=+010.000000
ERROR
LO=-010.000000
-----------------mm
HI=+010.000000
LO=-010.000000
p.145
Run
+002.654132mm

Step: 2 pts

PASS
+004.654321mm

Width

PASS
-----------------mm
Define
ERROR
-----------------mm
99.60ms
Judgment value
The judgment value for each output
number will be displayed.
HI: Judgment upper limit
LO: Judgment lower limit
Measurement value
Judgment result
---- will be displayed for output numbers
that have not been set.
99.60ms
99.60ms
Measurement items