Omron Z550 Operation Manual page 77

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

Step: 3 pts
Level differences, grooves, and other items of workpieces can be measured.
Specify two regions for the bottom face and one region for the top face. The difference, i.e., the
gap between the average of the bottom face measurements and the top face measurement, is
calculated.
The following conditions will be used as an example for describing the setting procedures.
1.
Select [Meas set].
A list of outputs appears.
2.
Select an output for which [Step: 3 pts] is set.
In this example, select [OUT1].
Setting Measurement Conditions (Expert Menu)
Difference
Scn 0
Set
Image
Detect set
Meas set
Extra set
Meas mode
Output
Scn 0
Set
OUT0:Height
OUT1:
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7:
SECTION 3
Z550
75
Operation Manual