Kyocera TASKalfa 7002i Service Manual page 816

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

U641
Communication time setting 2
(Message: Communication Time 2)
Contents
Sets the time-out time for the fax communication.
Purpose
Mainly, executed to improve the accuracy of communication for international communication
Method
1.Press the [Start] key.
2.Select the item to set.
Items
T0 TIME OUT
T1 TIME OUT
T2 TIME OUT
Ta TIME OUT
Tb1 TIME OUT
Tb2 TIME OUT
Tc TIME OUT
Td TIME OUT
Setting: T0 Time Out
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Sets to prevent disconnection of a line that occurs depending on the quality of the exchange, or
when the destination unit sets the auto switching function.
1.By using the [+] [-] keys or the numeric keys, change the setting value.
Sets the T0 time-out time.
2.Press the [Start] key to set the setting value.
* :[Completed] is displayed.
Setting: T1 Time Out
Sets the time before receiving the correct signal after call reception.
*This setting is usually unnecessary.
1.By using the [+] [-] keys or the numeric keys, change the setting value.
Sets the T1 time-out time.
2.Press the [Start] key to set the setting value.
* :[Completed] is displayed.
Setting: T2 Time Out
Sets the T0 time-out time.
Sets the T1 time-out time.
Sets the T2 time-out time.
Sets the Ta time-out time.
Sets the Tb1 time-out time.
Sets the Tb2 time-out time.
Sets the Tc time-out time.
Sets the Td time-out time.
Contents
Contents
6-223
Contents
Setting
range
30 to 90 s
56
58 (100 V model)
Setting
range
30 to 90 s