U465
ID correction data
(Message: ID Adjustment Data)
Contents
Refer s to the ID correction data.
Purpose
Execute for data check.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen is switched.
Items
TCONT
Laser Power
Laser Power(En)
Laser Power(Drum)
Laser Power(Max)
Bias Calib
T7 CTD
Stress
Refer ence: TCONT
1.Select [TCONT].
* :The current value is displayed.
Display
Before(K)
After(K)
Reference: Laser Power
* :The current value is displayed.
Items
K
Reference: Laser Power(En)
* :The current value is displayed.
Items
K
Developer bias control value after ID correction
Display the light intensity control value.
Display the exposure level (En)
Display the half exposure level of the drum (Drum)
Display the maximum exposure level (Max)
Sensor value for the toner layer calibration
T7 control value
Primary transfer belt durability
Black developer bias control value before ID correction
Black developer bias control value after ID correction
Displays the Black light intensity control value.
Displays the Black light intensity control value.