Kyocera TASKalfa 7002i Service Manual page 697

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

Setting: Low Power Mode
1.Select the mode to set.
Items
Mode0
Mode1
Mode2
* :Initial setting: Mode0
2.Press the [Start] key to set the setting value.
Setting: Belt Mode
1.Select the mode to set.
Items
On
Off
* :Initial setting: 1(On)
2.Press the [Start] key to set the setting value.
Setting: Ready Time Adjust
1.Change the setting value by using [+] [-] key or the numeric keypad.
Items
Value
Activating temperature correction value
low-temperature Aging: (α)
2.Press the [Start] key to set the setting value.
*: If the alpha value lowers, the aging activated temperature executing after the steady at a quiet mode
becomes lower.
*: Lowering the alpha value could deteriorate the fuser performance due to aging would not be activated
during quiet mode.
Temperature to
aging activation
Aging time
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Present state control mode (Usually not used)
Fuser temperature step-down mode
Productivity reduction mode
If the lower power mode transition time is 2 minutes or more, it enters
into the press heater control mode (low power mode)
IH control until the low power mode transition time
Contents
Less than 13+α°C
60 seconds
6-104
Contents
Contents
Setting range
0 to 5
13+α°C or more
35 seconds
2WA/2NJ/2RK
Data
Initial
variation
setting
1
2.0
18°C or more
0 sec

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taskalfa 8002iTaskalfa 9002i

Table of Contents