Kyocera TASKalfa 7002i Service Manual page 652

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

U070
DP magnification adjustment
(Message: Adjust DP Motor Speed)
Contents
Adjusting the magnification for DP scanning.
Purpose
Adjusted if the magnification is incorrect in the auxiliary scanning direction when the DP is used
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original on the DP and press the [Start] key to make a test copy.
* :Check the duplex scanning by setting [Duplex] when test copying.
4.Press the [System Menu] key.
5.Select the item to adjust.
Items
Sub Scan (F) Adjusting the magnification for table scan-
Main
Scan(CIS)
Sub Scan
(CIS)
*: Initial setting value is a reference value as the value changes by the adjustment at the production.
Adjustment: Sub Scan (F)/Sub Scan (CIS)
1.Change the setting value by using [+] [-] key or the numeric keypad.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image get longer, and it shortens when the setting
value is decreased.
2.Press the [Start] key to set the setting value.
Contents
ning
Adjusts the back side of the main scan-
ning direction magnification when duplex
scanning (CIS)
Adjusts the back side of the sub scanning
direction magnification when duplex scan-
ning (CIS)
Original
Setting range
-125 to 125
-125 to 125
Copy
Copy
example 2
example 1
Figure 6-11
6-59
2WA/2NJ/2RK-2
Data
variation
0.02%
0 to 75
0.02%
0.02%
Initial
setting
0
0
0

Hide quick links: