Setting: B/W Level1
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
Items
Original1
Sets the threshold which judges as the
original
Original2
Sets the threshold which judges as the
original
Original3
Sets the threshold which judges as the
original
* :Lowering the setting value improves the sensor's sensitivity and high density originals can
be detected but the original mat is possible of mis-detection as an original.
* :If each setting value is too with a difference, there is possible of mis-detection on the condi-
tion of placing the original.
Original mat
1
2
297mm
3.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Fig.
1
2
3
3
Figure 6-16
6-71
Setting range
0 to 255
0 to 255
0 to 255
Original
Original width size range
R/G/B
1
A4R to A3
2
B6R to A4R
3
to B6R
2WA/2NJ/2RK
Data
Initial
variation
setting
1
50
1
50
1
50
8.5" to 11"
5.5" to 8.5"
to 5.5"