Kyocera TASKalfa 7002i Service Manual page 796

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

U601
Initialize: Keep data
(Message: Initialize: Keep Data)
Contents
Initializes software switches other than the machine data on the FAX PWB according to the des-
tination and OEM setting.
Purpose
Initialize the FAX PWB without changing the user registration data and the factory defaults
Method
1.Press the [Start] key.
2.Select the [Execute].
* :The screen for entering the destination code and OEM code is displayed.
Items
Execute
3.Select [Country Code].
4.By using the [+] [-] keys or the numeric keys, change the setting value.
* :Refer to the destination code list. (See page P.6-201 )
Items
Country Code
OEM Code
* :No need to change the default value of [OEM Code].
5.Press the [Start] key to set the setting value.
* :Data initialization starts.
Press the [Stop] key to cancel the data initialization.
6.The firmware version is displayed after the data initialization.
The firmware version of 3 types of application, boot and IPL is displayed.
* :When initialization is successful, "Completed" is displayed for one second.
Executing data initialization
Setting Destination code
Sets the OEM code
6-203
Contents
Contents
2WA/2NJ/2RK

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taskalfa 8002iTaskalfa 9002i

Table of Contents