U131
Toner sensor control voltage adjustment
(Message: Adjust Toner Sensor Control Voltage)
Description
Adjusts the toner sensor control voltage
Purpose
if control values are not correctly read out due to the developer unit EEPROM failure etc., set
manual adjustment and fix temporarily control value in manual.
Execution
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Items
Manual
Auto
Mode
Setting: Manual
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
Items
Control(K)
Toner sensor K control voltage
3.Press the [Start] key to set the setting value.
Method: Auto
1.The current setting is displayed.
Items
Default(K)
Control(K)
Method: Mode
1.Select the item to set.
Items
Manual
Auto
* :Initial setting: Auto (0)
2.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Toner sensor control voltage manual adjustment
Toner sensor control voltage automatic adjustment
Change manual adjustment/automatic adjustment
Contents
Toner sensor K default control voltage
Toner sensor K control voltage after correction processing
Toner sensor control voltage manual adjustment
Toner sensor control voltage automatic adjustment
6-87
Contents
Setting range
Data
varia-
tion
0 to 255
1
Contents
Contents
2WA/2NJ/2RK-2
Initial setting
90
80
70
ppm
ppm
ppm
133
133
125