4. Release two hooks (a) and remove the
cover (b).
5. Release the hook (a) and remove the
separation pulley (b) from the shaft.
*: Check that the contact between the
paper feed pulley and separation pulley
is released.
6. Clean or replace the forwarding pulley,
paper feed pulley and separation pulley.
7. Reattach the forwarding pulley, paper
feed pulley and separation pulley in the
original position of the primary paper
feed unit.
*: Attach them while checking the color of
the collar.
Forwarding pulley (Collar: white)
Paper feed pulley (Collar: white)
Separation pulley (Collar: black)
When replacing the forwarding pulley, paper feed pulley and separation pulley, execute U903 (Jam counter
clear). (ReferP.6-238)
Clearing the maintenance counts (maintenance mode U251): Clear (ReferP.6-147)
b
a
4-70
2WA/2NJ/2RK
a
Figure 4-98
b
Figure 4-99